Permit: T00CM05075

Parcel: 138143290

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
02/06/2004 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
01/20/2004 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) GROUND METAL J-BOXES 2) NAIL PLATE CONDUCTORS WITHIN 1 1/4" OF STUD EDGES 3) ISNTALL SWAMP COOLER CIRCUIT 4) BASE BOARDS HEATERS REQUIRE INDIVIDUAL CIRCUITS 5) SUPPORT CONDUCTORS WITHIN 6' OF METAL J-BOXES 6) FAN BOX CANNOT BE MOUNTED WITH SCREWS
01/07/2004 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999* 1) BASE BOARD HEATER NUST BE ON A SINGLE DEDICATED ELECTRIC CIRCUIT. 2) ELECTRIC OUTLETS REQUIRED WITHIN 6 FEET OF DOOR WAYS EACH SIDE ON WALLS 2 FEET OR LONGER AND SPACED NOT MORE THAN 12 FEET APART MEASURED ALONG WALL LINE. 4) FAN BOX CANNOT BE SECURED WITH DRY WALL SCREWS. 5) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACES.