Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T00CM05027

Parcel: 116042950

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/19/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
11/21/2000 EXT METAL CLIPS/EXT SHEATHING Partial Approval CHECK FOR MTT 28B. AT INTERMEDIATES OK TO LATHE.
11/15/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*1. SEVERAL ROOF PANELS LOOSE/NAIL OFF. 2. SEVERAL DOUBLE TOP PLATES NOT CABIN TIED OR LAPPED MIN. 48" PROVIDE APPROVED STRAPPING. 3. NO TRUSS CALC'S AT INSPECTION THEY ARE NEEDED AT EVERY FRAMING INSPECTION ( 01025, 01030, 01035) 4. PROVIDE DETAIL 10/DT1 PER PLAN. 5. COMPLETE FRAMING OVER DETAIL 10/DT1 6. REPLACE 3- PAHD42 AT STARTING AT N/W CORNER BACK OF HOUSE EAST 3 HOLDDOWNS.
11/14/2000 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*