Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/24/2000 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
11/21/2000 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/1. NAILS MISSING AT CARPORT POST CAP. 2. ITEMS NOT COMPLETE AS PREVIOUSLY ADVISED. 3. PAHD AT FRT WINDOW CONSIDER USING ALTERNATE. | |
11/17/2000 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/1. SHEAR PANELS MUST BE NAILED AT MAX SPACING OF 6" O.C. AT EDGES AND 12" IN FIELD ALL EDGES MUST BE SUPPORTED AND NAILED. 2. HOLD DOWN WEST OF 5040 WINDOW MUST BE NAILED TO SHEAR PANEL AND TO FULL LENGTH DOUBLE STUDS NOT TRIMMERS. 3. ROOF SHEATHING A S.W. CORNER NOT NAILED. 4. O.S.B. ROOF SHEATHING MUST SPAN 2 BAYS, 3 TRUSSES. |