Permit: T00CM05024

Parcel: 115072060


Addresses:

149 W LEE ST


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T00CM05024

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/24/2000 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
11/21/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. NAILS MISSING AT CARPORT POST CAP. 2. ITEMS NOT COMPLETE AS PREVIOUSLY ADVISED. 3. PAHD AT FRT WINDOW CONSIDER USING ALTERNATE.
11/17/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. SHEAR PANELS MUST BE NAILED AT MAX SPACING OF 6" O.C. AT EDGES AND 12" IN FIELD ALL EDGES MUST BE SUPPORTED AND NAILED. 2. HOLD DOWN WEST OF 5040 WINDOW MUST BE NAILED TO SHEAR PANEL AND TO FULL LENGTH DOUBLE STUDS NOT TRIMMERS. 3. ROOF SHEATHING A S.W. CORNER NOT NAILED. 4. O.S.B. ROOF SHEATHING MUST SPAN 2 BAYS, 3 TRUSSES.