Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T00CM05018
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/19/2000 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
12/18/2000 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/1. P.E.X. AND ABS PLUMBING WITHIN 1 1/4" OF STUD SURFACE REQUIRE NAIL PROTECTION. 2. CORNERS WITH NON OVERLAPPING DOUBLE TOP PLATES REQUIRED STRAPPING. 3. NO TRUSS DRAWINGS ON SITE (7TRUSSES IN GARAGE MISSING RAT RUNS?) |