Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/28/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 11/17/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. PROVIDE BLK'S AT EDGE OF SHEAR IN FRT OF GARAGE. 2. SHEAR NOT COMPLETE AT NORTH WALL EXT. PER/PLAN 3. A35 RAFTER TO WALL. 4. STRAP ENTRY TRUSS. 5. CLIP TRUSSES TO WALLS. 6. PLAN CALLS FOR PLYWOOD CLIPS AT 24" O.C. WHERE ARE THEY PAGE 3 OR NOTES. |