Permit: T00CM04979

Parcel: 116112450

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/28/2000 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
11/17/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. PROVIDE BLK'S AT EDGE OF SHEAR IN FRT OF GARAGE. 2. SHEAR NOT COMPLETE AT NORTH WALL EXT. PER/PLAN 3. A35 RAFTER TO WALL. 4. STRAP ENTRY TRUSS. 5. CLIP TRUSSES TO WALLS. 6. PLAN CALLS FOR PLYWOOD CLIPS AT 24" O.C. WHERE ARE THEY PAGE 3 OR NOTES.