Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/19/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/16/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/1. PROVIDE 3 HOLDOWNS NOT INSTALLED. 2. PROTECT ELEC. ROMEX THRU OUT WITH 1 1/4 FROM EDGE OF STUD. 3. FHA STRAP AT OVER KNOTCHED DBL TOP PLATES. 4. SMOKE DETECTOR WITHIN 36" OF AIR DUCT. 5. DRAFT STOP IN CAVITIES BLOWN OUT. 6. SECURE GAS LINES PER UPC TABLE 12.2. 7. SECURE PEX 4' O.C. 8. PROVIDE TEST AT 2ND FLOOR. 9. SWEEP 2ND FLOOR NEED TO VARIFY NAIL SCHEDULE AT FLOOR SHEATHING. |