Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/22/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 11/30/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. 1/10 REQUIRES CLIPS ON STUDS AT BOTTOM PLATES EAST WALL. 2. PLAN CALLS FOR 2 X 10 BARGE RAFTERS 2 X 4 INSTALLED. 3. FRAME PLAN CALLS FOR TJI'S (INSTALLED) BUT SHEET 10 IS FOR LUMBER FRAME.(REVISE). 4. INTERBEAING WALLS REQUIRE WEB STIFFNERS AND ROTATION BLOCK. OK TO DRY IN ROOF. |
| 11/28/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
NO PLANS OR PERMITS ON SITE. |