Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/28/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 12/15/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. PROVIDE ANCHOR BOLTS WITHIN 12" OF SOLE PLATE SPLICES AT BEARING WALLS INTERIOR DRAG TRUSS WALL AT GARAGE AND AT ENTRY. 2. SECURE POST TO BEAM BACK COVERED PATIO BOTH SIDES. 3. PEX LINE IN CONTACT WITH METAL RCWB STRAP ISOLATE. 4. DRAFT STOP COLUMN AT ENTRY. 5. PROTECT ELECTRICAL ROMEX WITHIN 1 1/4 OF STUD BACK MASTER BEDROOM WALL. 6. ROMEX CABLE PROTECTIVE SHEATHIN SHALL ENTER BOX 1/4 INCH AT SMOKIE HALL LOCATION. 7. MECHANICAL PLATFORM NOT 24" WIDE AT ATTIC ACCESS BLOCK BETWEEN. 8. ELEVATION SHEET 5 ILLUSTRATES AS IS SHEATHIN IN LIEU OF FOAM BOARD REVISE PLAN OR OMIT INTERIOR VENTS NOT INSTALLED. |