Permit: T00CM04925

Parcel: 137336640


Addresses:

6245 S ARGOSY PL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/06/2000 FRAMING Approved IVRS - Inspection 0000*
12/04/2000 FRAMING Denied IVRS - Inspection 0920*
12/04/2000 FRAMING Partial Approval 1. COMPLETE ROMEX AT HOT WATER. 2. INSTALL REFRIGERANT LINES/CONDENSATE LINES. 3. BLOCK MECHANICAL 3 SIDES. 4. PROVIDE COIL STRAP 12" PASSED EACH SIDE OF OVER KNOTCH AT LAUNDRY AS PER ENGINEERS FIX. 5. SECURE PEX LINES HORIZONTALLY 48" O.C. AS PER MANF. SPECS. 6. SECURE ROMEX AT EXHAUST FAN WITHIN 10" OF DEVICE. 7. DRY IN ROOF IN ORDER TO VARIFY CLEARANCE FROM COMBUSTIBLE MATERIAL. 8. PROVIDE FIX FOR BLOWN OUT DOUBLE TOP PLATE OVER ELEC. PANEL.