Date Description Inspector Results Comments
02/13/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
02/09/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/SEE LAST INSP. ROOF.
02/08/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/1. ADD 2 X 4 UNDER GLU LAM FRONT ENTRY SOUTH END. 2. SHIM TJI GARAGE INTERIOR BEARING WALL. 3. SECURE TJI FRONT BEDROOM NO HANGER. 4. NAIL PLYWOOD ROOF DRYER DUCT AREA MARKED IN BLACK.
02/05/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/1. ADD STUD SOUTH END GLU LAM FRONT ENTRY 1 1/2" BEARING 2. BLOCK BELOW PARAPETS AND TOE NAIL. 3. SECURE PARAPET TO WALL GARAGE FRONT. 4. MISSED NAILING ROOF DECK WEST SIDE. 5. SECURE END TJI NEXT TO BEAM FRONT BEDROOM 6. SHIM TJI AT INT. BEARING.