Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/15/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
02/13/2001 | FRAMING | Not ready for Inspection | 1. PYRO-CURE PAPER AT F/PLACE. 2. SECURE FLUE F/PLACE. 3. BLOCK OFF FIRE PLACE CHASE 4. CUT NAIL BOTTOM PLATE DEN BEHIND GARAGE. | |
02/09/2001 | FRAMING | Denied | IVRS - Inspection 0999*/1. ZERO GAS TEST PRESSURE. 2. TIGHTEN H.D.'S 3. ADD CUT NAILS BOTTOM PLATE FRONT BEDROOM-BATHROOM WEST SIDE 4. FIRE PLACE FLUE SECURE AND KEEP 1" CLR. COMBUSTIBLES. 5. BLOCK OFF TOP OF SUPPORT CHASE. 6. GAS SIZE (PIPE) 7. SPECIAL TUB (NOT INSTALLED JACCUZZI?) 8. BLOCK ALL DUCTS. 9. SEE ORANGE MARKS ON FLR. |