Permit: T00CM04815

Parcel: 114469000

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T00CM04815

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/05/2001 BUILDING - FINAL Approved IVRS - Inspection 0000*
03/02/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/1. WATER HEATER AND FURNACE VENTS WITHIN 4 FEET OF VERTICAL WALL MUST EXTEND 1 FT ABOVE WALL. 2. FURNACE VENT MISSING WEATHER CAP 3. A.B.S. PLASTIC VENTS ON ROOF MUST HAVE LATEX PAINT PROTECTION. 4. MAX ALLOWED A/C FUSE /CB-45 AMP. 50 INSTALLED.