Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T00CM04815
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/05/2001 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
03/02/2001 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/1. WATER HEATER AND FURNACE VENTS WITHIN 4 FEET OF VERTICAL WALL MUST EXTEND 1 FT ABOVE WALL. 2. FURNACE VENT MISSING WEATHER CAP 3. A.B.S. PLASTIC VENTS ON ROOF MUST HAVE LATEX PAINT PROTECTION. 4. MAX ALLOWED A/C FUSE /CB-45 AMP. 50 INSTALLED. |