Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T00CM04762
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/05/2001 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
12/29/2000 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000* | |
12/28/2000 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/1. MISSING NAILING ON THE ROOF AND AT SHEARWALLS. 2. SHEATHING FUR PARALELL TO TRUSSES, MUST BE BLOCKED 3. NEED TRUSS SHOP DRAWINGS FOR THIS HOUSE. 4. ATTACH SHEAR WALL GARAGE TO HOUSE WALL PER DETAIL 11/8A. 5. TSC 24 TRUSS CLIPS AREN'T NAILED CORRECTLY. 6. ENTRY ROOF FRAMING NEEDS ATTENTION. |