Permit: T00CM04762

Parcel: 136238800

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T00CM04762

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
01/05/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
12/29/2000 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
12/28/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. MISSING NAILING ON THE ROOF AND AT SHEARWALLS. 2. SHEATHING FUR PARALELL TO TRUSSES, MUST BE BLOCKED 3. NEED TRUSS SHOP DRAWINGS FOR THIS HOUSE. 4. ATTACH SHEAR WALL GARAGE TO HOUSE WALL PER DETAIL 11/8A. 5. TSC 24 TRUSS CLIPS AREN'T NAILED CORRECTLY. 6. ENTRY ROOF FRAMING NEEDS ATTENTION.