Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 03/02/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Approved |
IVRS - Inspection 0000* |
| 03/01/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Denied |
IVRS - Inspection 0925*/NO PLAN REVISION OR JOINT USE SEWER AGREEMENT ON SITE. NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE. |
| 02/26/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Denied |
IVRS - Inspection 0950*/NO REVISED PLAN OR JOINT USE AGREEMENT ON SITE. |
| 02/16/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Denied |
IVRS - Inspection 0999*/1. SEWER LOCATION ON SITE PLAN IS NOT PER PLAN SEWER PLAN CALLS FOR SEWER ON WEST SIDE OF FRONT HOUSE IN EASEMENT. PRESENTLY CONNECTED TO MAIN HOUSE SEWER ON EAST SIDE. YOU MUST OBTAIN A JOINT USE SEWER AGREEMENT AND YOU MUST PROVE THAT THE MAIN HOUSE TO HCS SEWER LINE IS 4" OR GREATER DUE TO 4 OR MORE WATER CLOSETS ON LINE AND LINE CARRIES MORE THAN 35 FIXTURE UNITS. |