Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/02/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 04/27/2001 |
FRAMING |
|
Denied |
1) FIREPLACE CHIMNEY REQ'S 1" TO COMBUSTIBLE 2) M/BATH TUB AND SHOWER NOT IN 3) M/BATH LAV TRAP WEIR ? HIGHER THAN VENT OPENING AT W/C 4) M/BATH LAV OUTLET MISSING IN BOX 5) SEAL FLOOR PENETRATIONS FROM SOIL 6) BOND GAS LINE 7) KITCHEN COUNTER BOX NOT WIRED |
| 04/23/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1) SEAL RACEWAYS AT ELEC PANEL 2) SECURE GAS LINE EVERY 8' 3) PROVIDE BOX FOR LIGHT AT BATHROOM'S 4) DRAFT STOP AT CHIMNEY 5) ANCHOR BOLT BEHIND CHIMNEY LOOSE AND THROUGHOUT HOUSE 6) PROVIDE GOOD WORKING GAGE AT GAS LINE 7) PROTECT VENT AT SHOWER 8) PROTECT ELEC WIRE AT SHOWER 9) GROUND ALL BOXES |