Permit: T00CM04674

Parcel: 111063880

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/12/2002 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
03/08/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0245*1.) UNITS NOT ENERGZIED, INSPECTOR WILL NOT TURN MAIN BREAKERS ON 2.) PUSH IN GROMMETS NOT APROVED UNLESS CLAMP TYPE, ITEM #5.
02/20/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0245*NOTES 1.) SOME OUTLETS NOT ENERGIZED 2.) CONDUIT IN WATER HTR ROOM TO BE INSULATED WHERE TOUCHING COPPER WATER LINE. 3.) INSTALL BREAKER LOCK-OUT FOR WATER HTR. BREAKERS. 4.) PLEASE POWER CHECK ALL DEVICES PRIOR TO FINAL INSPECTION. 5.) INSTAL ROMEX CONNECTORS ON FUME HOOD IN KITCHEN.
10/08/2001 ELECTRIC - FINAL Denied 1.) #6 WIRE FOR SUB PANEL NOT ADAQUATE FOR 100 AMP CIRCUIT BREAKER SIZE PER N.E.C. 2.) SEAL ROOF PENETRATION PROPERLY WATER IS LEAKING THRU. RAIN.