Permit: T00CM04655

Parcel: 123023280


Addresses:

2600 E SENECA ST

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
11/09/2010 ROOF NAILING Approved IVRS - Inspection :*
11/08/2010 ROOF NAILING Not ready for Inspection IVRS - Inspection :*
11/03/2010 ROOF NAILING Cancelled IVRS - AP canceled
09/24/2010 ROOF NAILING Partial Approval PENDING REVISION
03/21/2001 ROOF NAILING Partial Approval
02/21/2001 ROOF NAILING Denied IVRS - Inspection 0999*/1. CANNOT APPROVE FRAME UNTIL MECHANICAL, ELECTRIC AND PLUMBING ARE COMPLETE. 2. MECHANICAL NOT PER PLAN PLAN CALLS FOR INTERIOR FURNACE. PRESENTLY FOR ROOF MOUNTED UNIT. 3. REVISE ROOF FRAME PLAN FOR ADDED AND OVERSIZED SKYLIGHTS AND CUT AND HEADERED TJI'S. 4. INCORRECT HANGERS USED ON TJI'S-LU26'S AND LU 48'S FOR DIMENTIONAL LUMBER. NOTE: WASTE VENT CONNOT TERMINATE WITHIN 1 FOOT OF VERTICAL SURFACE.