Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/09/2010 |
ROOF NAILING |
|
Approved |
IVRS - Inspection :* |
| 11/08/2010 |
ROOF NAILING |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 11/03/2010 |
ROOF NAILING |
|
Cancelled |
IVRS - AP canceled |
| 09/24/2010 |
ROOF NAILING |
|
Partial Approval |
PENDING REVISION |
| 03/21/2001 |
ROOF NAILING |
|
Partial Approval |
|
| 02/21/2001 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*/1. CANNOT APPROVE FRAME UNTIL MECHANICAL, ELECTRIC AND PLUMBING ARE COMPLETE. 2. MECHANICAL NOT PER PLAN PLAN CALLS FOR INTERIOR FURNACE. PRESENTLY FOR ROOF MOUNTED UNIT. 3. REVISE ROOF FRAME PLAN FOR ADDED AND OVERSIZED SKYLIGHTS AND CUT AND HEADERED TJI'S. 4. INCORRECT HANGERS USED ON TJI'S-LU26'S AND LU 48'S FOR DIMENTIONAL LUMBER. NOTE: WASTE VENT CONNOT TERMINATE WITHIN 1 FOOT OF VERTICAL SURFACE. |