Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T00CM04624

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/29/2000 FRAMING Approved IVRS - Inspection 0000*
11/28/2000 FRAMING Denied IVRS - Inspection 0999*/1. REPLACE 2 RED HEAD A.B.'S BY ELECT SERVICE. 2. HIP HANGERS NOT NAILED. 3. NAIL PROTECT PEX WITHIN 1 1/2" OF STUD SURFACE. 4. RED HEAD ANCHOR BOLTS LOOSE THROUGHOUT. 5. FIRE BLOCK STAIRS. 6. BLOCK VENTS. 7. CALL IN ALL TRADES. 8. DUCT RESTRICTED AT DINING ROOM. TOP TIGHT OF BEND AT DEFUSER BOOT. 9. FILL ALL NAIL HOLES IN FHA STRAPS AT A/C LINES. DOUBLE TOP PLATE. 10. RETURN AIR DUCT RESTRICTED ALSO SUPPLY AND DUCT LOOSE. 11. NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE. 12. MANY TRUSS U 24 HANGERS NOT NAILED REMOVE ALL BLOCKING FOR INSPECTION.