Permit: T00CM04622

Parcel: 119216140

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T00CM04622

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/27/2000 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/1. PROVIDE GAS TEST MIN. 10 PSI. 2. PROVIDE MIN. 1" CLEARANCE FROM COMBUSTIBLES AT ALL FLUES. 3. STRAP OVER BORED WATER AND GAS AT DBL. TOP PLATE. 4. ATTIC ACCESS BLOCKED WITH MECHANICAL. 5. DRYER DUCT NOT THROUGH ROOF. 6. SUPPORT 90 DEGREE VTR, HALL LAUNDRY. 7. EXHAUST FAN AT MASTER BATH INSTALLED UPSIDE DOWN. 8. CONDENSATION NOT COMPLETE AT FURNACE.
10/23/2000 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/1. BLOCK STUB TRUSSES (A3) AT BOTTOM, WILL CHECK AT INTERMEDIATES. 2. PROVIDE DETAIL 13/DO1, WILL CHECK AT INTERMEDIATES.