Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM04618
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/21/2000 | FRAMING | Approved | IVRS - Inspection 0000*/DRAIN TEST DONE BEFORE PLUMBING REPAIR. | |
| 11/20/2000 | FRAMING | Denied | IVRS - Inspection 0999*/1. STILL NEGATIVE PITCH ON MASTER SINK DRAIN LINE IN GARAGE CEILING-OVER DRYER VENT PIPE. | |
| 11/17/2000 | FRAMING | Denied | IVRS - Inspection 0999*/1. NEW INSTALLATION OF DRYER VENT HAS CAUSED A NEGATIVE PITCH IN THE SINK DRAIN LINE, IN THE GARAGE, COMING DOWN FROM THE MASTER BATH. | |
| 11/16/2000 | FRAMING | Denied | IVRS - Inspection 0999*/1. DRYER VENT DUCT NOT INSTALLED. 2. BLOCK STUD BAY BETWEEN COMBUSTION/RELIEF AIR IN GARAGE. 3. MISSING H2.5 ON TGI OVEN KITCHEN STOVE. 4. STOVE OUTLET NEEDS SECURE INSTALLTION. 5. NEED SHIMMING OVER KIT WINDOW HEADER. 6. UNNAILED RAFTER CLAMPS AT GLUE LAM OVER STAIRS. 7. OUTLET ADJACENT TO MASTER TUB IS HAZARDOUS LOCATION. | |
| 11/15/2000 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |