Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T00CM04582
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/09/2001 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection 0000* | |
10/16/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000$PA 5. LIFT. | |
10/15/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1ST LIFT CORNER N. WALL. | |
10/08/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
10/04/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
10/01/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
09/25/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000$PA 1ST LIFT @ N SIDE 2ND LIFT @ S SIDE. | |
09/20/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000$1ST LIFT. | |
09/19/2001 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000$PA @ 1ST LIFT. |