Permit: T00CM04572

Parcel: 110065360


Addresses:

2945 N CARDELL CI

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/05/2001 FRAMING Approved IVRS - Inspection 0000*
11/13/2000 FRAMING Denied IVRS - Inspection 0999*/1. GARAGE SHEARWALL 1 DOUBLE TOP PLATE CUT. PROVIDE ENGINEERS AND C.O.T APPROVED REPAIR. WALL MUST GO TO ROOF. MECH., ELEC. AND PLUMBING MAYBE AFFECTED. 2. SHEARWALL STUD MISSING BY RANGE HOOD. 3. BLOCK SHEAR WALL 3 FOR TOP PLATE NAILING AT GARAGE. 4. FIRE BLOCK DEAD SPACES ON NORTH WALL AND BATHROOMS. 5. NAIL PROTECT RANGE 220V CABLE WITHIN 1 1/4" OF STUD SURFACE.