Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/27/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/22/2000 |
FRAMING |
|
Partial Approval |
1. SECURE ROMEX CABLE TO CENTER OF STUD. 2. PROTECT ROMEX WITH 1 1/4 FROM EDGE OF STUD. 3. PROVIDE NEC. 370-17 (C) TWO CABLES CANNOT BE NAILED ON EDGE. 4. STRAP SECURE GAS LINE IN ATTIC. 5. CANNOT APPROVE FRAMING INSP. UNTIL ALL INTER. APPR. |
| 11/21/2000 |
FRAMING |
|
Partial Approval |
1. COMPLETE (ROMEX WIRE) AT EXHAUST FAN. 2. STRAP SECURE 90 DEGREE VTR AT HALL BATH. 3. PROTECT ELECTRICAL WITHIN 1 1/4 FROM EDGE OF STUD SECURE VERTICAL AT CENTER OF STUDS. PROVIDE TEST. |