Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T00CM04548

Parcel: 107140210


Addresses:

519 E ALTURAS ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
09/25/2000 BUILDING - FINAL Approved IVRS - Inspection 0000*
09/14/2000 BUILDING - FINAL Denied 1. ABS PLASTIC VENTS ON ROOF REQUIRE LATEX PAINT. 2. 519 ADDRESS REQUIRED ON HOUSE IN MINIMUM 3" HIGH NUMBERS. 3. CONCRETE STOOP REQUIRED AT FRONT DOOR-DOOR WIDTH BY 30" DEEP. 4. OUTSIDE HOSE BIBS REQUIRED ANTI SIPHON VALVES. 5. ELECTRIC SUB PANEL MUST HAVE AN ISOLATED NEUTRAL BAR. 6. WATER HEATER "B" VENT PLUGGED WITH TAPE REMOVE TAPE FROM DOUBLE WALL VENT. 7. W/H T AND P LINE MUST EXHAUST DOWN.