Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/25/2000 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 09/14/2000 |
BUILDING - FINAL |
|
Denied |
1. ABS PLASTIC VENTS ON ROOF REQUIRE LATEX PAINT. 2. 519 ADDRESS REQUIRED ON HOUSE IN MINIMUM 3" HIGH NUMBERS. 3. CONCRETE STOOP REQUIRED AT FRONT DOOR-DOOR WIDTH BY 30" DEEP. 4. OUTSIDE HOSE BIBS REQUIRED ANTI SIPHON VALVES. 5. ELECTRIC SUB PANEL MUST HAVE AN ISOLATED NEUTRAL BAR. 6. WATER HEATER "B" VENT PLUGGED WITH TAPE REMOVE TAPE FROM DOUBLE WALL VENT. 7. W/H T AND P LINE MUST EXHAUST DOWN. |