Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/08/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/06/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/NEXT FAILURE WILL INCUR REFEE. ITEMS 2,3,4,6 FROM ABOVE NOT CORRECTED. |
| 10/31/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. FAU REGISTERS NOT ADEQUATELY SUPPORTED (BLOCK 3 SIDES) 2. REPLACE TOP PLATE AT KITCHEN WALL. 3. SECURE ELECT HOMERUNS IN WALL CAVITY. 4. HANGERS USED AT FRONT GIRDER TRUSS ARE DESIGNED FOR TOE NAILING WITH MIN 10D NAILS. 5. BLOCK BETWEEN COMBUSTION AIR VENTS IN GARAGE. 6. PROVIDE BLOCKING AT WH PLATFORM FOR PERIMETER NAILING OF SHEETROCK. |