Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/27/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 12/21/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. WATER HEATER VENT MUST HAVE 1" CLEARANCE TO COMBUSTABLES 2. WATER HEATER VENT INSTALLED UPSIDE DOWN. 3. NAIL PROTECT PLUMBING WASTE DRAIN AT SHOWER SELL PLATE. 4. A.B.S. PLUMBING NOT ALLOWED OUTSIDE OF BUILDING BELOW ROOF LINE. 5. PLAN CALLS FOR V.T.R. IN LAUNDRY A.A.V. USED --REVISE PLAN. 6. REVISE PLAN TO INDICATE USE OF CORRIGATED STAINLESS STEEL GAS PIPE. 7. REVISE PLAN FOR CHANGED LAV LOCATION. |