Permit: T00CM04535

Parcel: 137293820


Addresses:

5177 S FOX TROT DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/20/2000 FRAMING Approved IVRS - Inspection 0000*
11/17/2000 FRAMING Partial Approval COMPLETE DETAIL 3/SD3 COMPLETE FLOOR SHEATHINS NAILING SCHEDULE, COMPLETE 6/SD3 NAIL SHEAR BLOCKS AT CANTILEVERED.
11/16/2000 FRAMING Denied 1. MECHANICAL NOT COMPLETE. 2. ANCHOR BOLT MISSING AT GARAGE GLUE LAMP. 3. PROVIDE KING STUDS AT OPENINGS GREATER THAN 8' SEE DETAIL 3SD3. 4. PROVIDE DETAIL SD3-10 BLOCK UNDER GIRDER AT GARAGE DETIAL 6 SD3 NOT COMPLETE. DETAIL 8SD3 NOT COMPLETE.