Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T00CM04505
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/13/2000 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
| 10/09/2000 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/1. H25'S MISSING AT MASTER BEDROOM WEST WALL TRUSSES. 2. X BRACE TRUSSES AT CENTER. 3. REAR SHEAR SHOULD GO PAST TRUSS. 4. NEED POST UNDER GIRDER AT GARAGE. 5. REAR PORCH NOT COMPLETE. |