Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 10/15/2004 |
ELECTRIC - INTERMEDIATE |
|
Approved |
|
| 04/06/2004 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) MINIMUM HEADROOMNOT MAINTAINED STAIRWELL 2) STAIR GUARD RAILS NOT TO CODE 3) CARPORT NOT BUILT YET 4) MUST COMPLETE ALL TRADES AND RECALL |
| 11/18/2003 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) MINIMUM HEAD ROOM NOT MAINTAINED STAIRWAY 2) MAXIMUM DISTANCE BETWEEN STAIR VERTICAL IS 4" (GUARD RAIL) 3) GROUND ALL METAL ELECTRIC BOXES (SOME STILL NOT DONE) 4) WILL NEED TO DRIVE 2-8" FOOT GROUND RODS MINIMUM 6' APART FOR NEW ELECTRIC PANEL EXTERIOR 5) INSTALL ELECTRIC RISER SUPPORT ON ROOF 6) CARPORT WIRING INCOMPLETE 7) COMPLETE AND RECALL |
| 06/26/2003 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) PLANS SHOW 200 AMP SERVICE PANEL (125 AMP EXISTING) 2) BASE BOARD HEATERS TO BE ON CORPORATE CIRCUIT (CIRCUITS # 15 AND 16) 3) PLANS CALLS FOR GFCI RECEPTACLE NEW BALCONY #2 4) PLAN CALLS FOR NEW GAME ROOM 3 OVERHEAD LIGHTS AND 3-3 WAY SWITCHES 5) MUST HARD WIRE SMOKE DETECTROS; ALSO EXTERIOR GFCI EXTERIOR 1ST FLOOR 6) PLAN CALLS FOR NEW FAMILY ROOM 2 OVERHEAD LIGHTS; DOUBLE SWITCH 7) CARPORT WIRING NOT DONE |
| 06/06/2003 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1) COMPLETE ALL TO APPROVED PLANS AND MINIMUM CODE 2) SUGGEST OBTAINING A LICENSED ELECTRICIAN TO CORRECT THESE REQUIREMENTS. |
| 05/14/2003 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) SECURE WIRES WITHIN 12" OF BOXES 2) GROUND ALL METAL BOXES 3) INSTALL ROMEX CONNECTORS ALL BOXES 4) MUST INSTALL APPROVED BOX CEILING FAN 5) INSTALL SEPARATE CIRCUIT BASE BOARD HEATERS (PERMANENTLY ATTACHED TO WALL) 6) SWITCHES, LIGHTS, OUTLETS NOT PER APPROVED PLAN 7) INSTALL BANG PLATE NAIL PROTECTION ELECTRIC WITHIN 1 1/2" OF STUD OF EDGE 8) STOPPED INSPECTION COMPLETE ALL AND RECALL |