Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T00CM04465
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/12/2000 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
| 12/11/2000 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/1. SHOWER REQUIRED TEMP/PRESSURE BALANCE VALVE. 2. MUST HAVE PLAN AND PROOF OF ALL PRIOR INSPECTIONS ON SITE. | |
| 12/05/2000 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/1. OUTSIDE HOSE BIBS REQUIRE ANTI SIPHON VALVES. 2. STOOP REQUIRED AT ENTRY DOOR. 3. SEAL EXTERIOR WALLS AT ELECTRIC FOR OUTLETS. 4. LABLE ALL CIRCUITS IN ELECTRIC PANEL. 5. RANGE HOOD MISSING WEATHER CAP. 6. ELECTRIC SERVICE REQUIRES NOW WATER BOND LABLE. 7. PLUMBING VENTS MUST EXHAUST OUTSIDE OF ATTIC 6" ABOVE ROOF. 8. FURNACE "B" VENT PLUGGED WITH TAPE. 9. YOU MUST PROVIDE LADDER FOR ATTIC INSPECTION. 10. SHOWER MUST HAVE TEMP/PRESSURE BALANCE VALVE. SEE PLUMB INTERMEDIATES ITEMS. 11. INADEQUATE NATURAL LITE. 3030 WINDOW OMITTED. 12. LIGHT SWITCHES MUST BE GROUNDED. 13. STUCCO AND INSULATION INSTALLATION CERTIFICATES REQUIRED. 14. GAS LINE MUST BE ELECTRICALLY BONDED. STOPPED INSP. |