Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/25/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 04/23/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1) SHEAR PANELS NOT FASTENED PER PLAN |
| 04/19/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
1) EXTERIOR OSB NOT NAILED TO ALL STUDS RE-NAIL TO ALL STUDS AT 8" 12" OC MAX SPACING 2) PORCHES LEDGERS MISSING A-35 CLIPS-TAB MUST BE NAILED OVER TOP OF LEDGERS-FRONT AND REAR PORCHES 3) FIRE BLCK ALL DROP CEILING AREAS 4) PORCH RAFTERS REQUIRE U-46 HANGERS U-26 HRR AT REAR H2-5 CLIPS AND A 35 CLIPS MAY USE H2-5 CLIPS BOTTOM OF FRONT AND REAR PORCH LEDGER STUDS AT 32" OC STUDS |
| 04/12/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/HOUSE ROOF OK PORCH NOT INSTALLED, LEDGERS AND BARGE RAFTERS CIPPED-HD'S AND SHEATHING NOT COMPLETED, OK TO DRY IN HOUSE ROOF ONLY |