Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/11/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 12/28/2000 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000* |
| 12/15/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. BEAM B-1 IS REQUIRED TO BE 3 1/2 X 10 METAL CHANNEL BEAM. BUT 3 1/2 X 12" G.L.B. INSTALLED BUILT TO PLAN OR REVISE PLAN TO AS BUILT AND HAVE APPROVED BY C.O.T. 2. ANCHOR BOLTS REQUIRED WITHIN 12" OF ENDS AND SPLICES OF MUD SILL. 3. ATTIC ACCESSS REQUIRED TO BE 22" X 30" MINIMUM. 4. GAS LINE MUST BE ELECTRICALLY BONDED WITH CLAMP VISIBLE AFTER CONTRUCTION. 5. BOND STEEL FRAME AT ATTIC ACCESS. 6. PLAN CALLS FOR GALV. METAL DUCT WORK AND FLEX USED REVISE PLAN AND HAVE APPROVED BY C.O.T. 7. SUPPORT 3/4" GAS LINE AT 8' O.C. OK TO INSULATE DO NOT COVER REPAIRS |