Permit: T00CM04420

Parcel: 110180010


Addresses:

2801 N LAUREL AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/23/2001 FRAMING Approved IVRS - Inspection 0000*
02/09/2001 FRAMING Denied IVRS - Inspection 0999*/NO CHANGE SITE CONFERENCE.
02/07/2001 FRAMING Denied IVRS - Inspection 0999*/1. PAHD42 HOLD DOWN REQUIRE A MINIMUM OF 12 EACH 16D NAILS ONLY 6-8 NAILS INSTALLED-HOLD DOWNS COVERED W/O INSPECTION EXPOSE. 2. DRYWALL SCREWS NOT ALLOWED FOR INSTALLATION OF SIMPSON HARDWARE. 3. LTT19 PERLIN ANCHORS NOT INSTALLED. 4. HTT22 HOLD DOWNS MUST BE ATTACHED TO FULL LENGTH DOUBLE STUDS NOT TO TRIMMERS. 5. PROVIDE TJI INSTALLATION INSTRUCTIONS FOR RAFTER TAILS AND LOOK OUTS.