Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T00CM04402
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/05/2001 | ELECTRIC - FINAL | Approved | ||
05/30/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999*ROOF:1)USE APPROVED CONNECTORS TO SEAL THE AT BATH HOOD, AND PROTECT SEAL IN TO UNIT, LOOSE FITTING, SEAL ROOF JACK.COLUMNS:1)LOOSE FITTINGS AT COLUMNS.USE APPROVED FITTINGS FOR G TO CABLE. | |
05/09/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* 1) FINISH ROOF 2) NEED PERMIT FOR SIGNS INTERIOR 3) CHECK BACK BAR LIGHTING FOR PROTECTION OF CONDUCTORS 4) NEED TO USE LISTED AND LABELED LIGHTING FIXTURES 5) RE SUPPORT MC CABLE OVER DJ STAND 6) CHECK FRONT COLUMNS |
|
03/16/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0920* LOCKED NO ACCESS | |
03/15/2001 | ELECTRIC - FINAL | Partial Approval | 1) OK FOR TEMP C OF O 2) SUPPORT CABLES V/D/V AS PER CODE-CON NOT SUPPORT OFF OF MC CABLES 3) NEED TO HAVE DISCO LIGHTING LISTED AND LABELED 4) NEED LETTER FROM ENGINEER REGUARDING SERVICE DIAGRAM 5) WORKING CLEARANCES IN FRONT OF A/C DISCONNECTS 6) NEED DISCONNECTING MEANS CONDENSING UNIT-ROOF 7) LOOSE A/C FITTINGS-ROOF 11) SUPPORT SEAL TITE FOR SIGN |
|
03/14/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* 1) FINISH INSTALLING LIGHT FIXTURES 2) SUPPORT D/V/D CABELS CORRECTLY - NOT OFF OF M/C CABEL 3) NEED EXIT SIGNS AS PER PLANS 4) MISSING FACE PLATES 5) NEED LISTING AND LABELING FOR DISCO LIGHTS 6) SUPPORT ALL CONDUIT AS PER CODE |