Permit: T00CM04400

Parcel: 141111400

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T00CM04400

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/08/2000 FRAMING Approved IVRS - Inspection 0000*
11/06/2000 FRAMING Denied IVRS - Inspection 0999*/1. FRONT DOOR HEADER AND FRONT WINDOW HEADER ARE NOT PER PLAN. 2. PATIO ROOF LEDGER NEEDS A35'S FOR HORIZONTAL STRENGTH. 3. STRAP BOTTOM OF KITCHEN GAS PIPE. 4. INSTALL BANG PLATE AT ELECTRIC LINE AT WEST KITCHEN SOLE PLATE. 5. BLOCK STUD BAY IN GARAGE BETWEEN COMBUSTION AND RELIEF AIR VENTS.