Permit: T00CM04371

Parcel: 140441830


Addresses:

5777 E FARMRIDGE DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/21/2000 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
11/15/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. INSTALL REHEAD ANCHORS AR ALL DRILLED HOLES IN BOTTOM PLATE. 2. INSTALL H2.5 CLIPS AT TOP AND BOTTOM OF EACH STUD. 3. EITHER REMOVE SIDING AND PROPERLY CLIP GABLE END TRUSSES TO TOP PLATES, OR INSTALL STRAPS INSIDE GARAGE TO TIE THE BOTTOM CORDS OF THE 2 TRUSSES TO THE TOP PLATES TO PREVENT UPLIFT.
11/08/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. ANCHOR BOLTS/RED HEADS MUST BE WITHIN 6" OF ALL CORNERS AND BOTTOM PLATE BREAKS. 2. ALTHOUGH SIDING NEGATES VIEWING EXTERIOR CLIPS, THERE DOES NOT APPEAR TO BE SIMPSON H2.5'S AT ANY OF THE STUDS, PER PLAN. ALSO, THE GABLE END TRUSSES SHOW NO CLIP ATTACHMENT TO THE TOP PLATE.