Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/26/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. SHEARWALL #2 FRONT PROVIDE SHEAR TRANSFER FROM SOLE PLATE THRU ROOF DIAPHRAM. 2. PROTECT PEX, ELEC WITHIN 1 1/4" FROM EDGE OF STUD. 3. LADDER BLOCKS NOT NAILED TO DBL TOP PLATE. 4. COMPLETE DRAFT STOP. 5. GROUT TUBS 6. FIX LEAK AT MASTER BATH TUB. 7. SECURE ABS 4' O.C. HORIZONTALLY. 8. PROVIDE DBL STUDS UNDER GIRDER AT FRONT CLIP BOTH SIDES. |
| 10/25/2000 |
FRAMING |
|
Partial Approval |
PENDING ROOF DRY IN AND EXTERIOR DRY IN. |