Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date |
Description |
Inspector |
Results |
Comments |
| 12/21/2000 |
REINFORCED MASONRY PRE-GROUT |
|
Approved |
IVRS - Inspection 0000* |
| 12/13/2000 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*/4FT LIFT OK. CALL FOR BOND BEAM INSPECTION PRIOR TO GROUTING SECOND LIFT. |
| 11/24/2000 |
REINFORCED MASONRY PRE-GROUT |
|
Denied |
IVRS - Inspection 0999*/1. VERTICAL REBAR REQUIRED AT 48" O.C. AND MUST EXTEND 20" ABOVE BLOCK. REBAR TO BE #4. 2. DURO WALL BLOCK REINFORCEMENT REQUIRED AT 16" O.C. (EVERY 2 BLOCKS) NOT INSTALLED. 3. BEDROOM WINDOW 4040 SILL CANNOT BE ABOVE 44". |