Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/01/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000*/1. PROTECTIVE BUSHING BEHIND PANEL NOT SECURED WIRES ARE IN DIRECT CONTACT WITH METAL PANEL. 2. SECURE ROMEX AT EXHAUST FANS WITHIN 10" 3. PROVIDE 36" BETWEEN AIR DUCT AND SMOKE DETECTOR. 4. DRAIN ARM FOR LAV. DOES NOT HAVE 1/4" A SLOPE PER FOOT. |
| 10/30/2000 |
FRAMING |
|
Denied |
1. SMOKE DETECTOR INSTALLED WITHIN 36" OF AIR VENT. 2. DRAFT STOP MASTER BATH BETWEEN SHOWER AND TUB WALL 3. SEAL SOLE PLATE SPLICES WHERE PENETRATED BY ABS TO PREVENT INFILTRATION. 4. FHA STRAP AT KITCHEN NOT INSTALLED IN FRONT OF GAS LINE. 5. DETAIL 2/DT1 NOT INSTALLED AS PER PLAN. 6. PROVIDE MINIMUM 10 PSI FOR GAS TEST 7. BUSHING BEHIND PANEL NOT INSTALLED PROPERLY 8. NO COT APPROVED TRUSS CALC'S ON SITE. |