Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T00CM04234
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/01/2001 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
05/31/2001 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/ 1) ELECTRIC OUTLET GFCI HOT WHEN TRIPPED 2) BARE BULB LIGHT FIXTURES NOT ALLOWED IN CLOTHES CLOSETS 3) WATER HEATER VENT INPROPERLY INSTALLED VENT CONNECTOR MUST CONNECT INSIDE OF INNER LINER OF "B" VENT, 6" CLEARANCE REQUIRED TO COMBUSTIBLES ON SINGLE WALL VENT 4) LABEL ALL CIRCUITS IN ELECTRIC SERVICE PANEL 5) FIREPLACE GAS LOG GAS LINE MUST HAVE FIRE PROOF CAULK AT FIRE PLACE PENETRATION 6) PROVIDE STUCCO AND INSULATION INSTALLATION CERTIFICATES NOTE: IS DISPOSAL AND DISH WASHER ON A MULTI WIRE CIRCUIT |