Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM04234
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/23/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
04/19/2001 | FRAMING | Partial Approval | IVRS - Inspection 0000*/1) KITCHEN COUNTERS WIDER THAN 12" MUST HAVE GFCI OUTLET 2) NO PRESSURE TEST ON GAS LINES 3) WATER HEATER "B" VENT NOT INSTALLED MUST HAVE 1" CLEARANCE TO COMBUSTABLES | |
04/18/2001 | FRAMING | Denied | IVRS - Inspection 0925*/NO ACCESS OR PLAN | |
04/17/2001 | FRAMING | Cancelled | IVRS - Ri canceled | |
04/02/2001 | FRAMING | Denied | IVRS - Inspection 0999*/1. WINDOWS ARE NOT PER PLAN. REVISE PLAN TO AS BUILT. 2. NAIL PROTECT WIRES AT N.W. CORNER TOP PLATE-WITHIN 1 1/4" OF STUD SURFACE. 3. GAS LINE REQUIRES ON ELECTRIC BOND. 4. EXISTING HOUSE HAS BEEN COMPLETELY REWIRE-HAD WATER CLOSET DRAIN LINE REPLACED, ADDED GAS LINE TO RANGE AND HAD ALL MECHANICAL DUCTS REPLACED WITHOUT INSPECTION. REVISE PLAN TO AS BUILT. | |
02/28/2001 | FRAMING | Partial Approval | IVRS - Inspection 0000*/FRAME OK WILL APPROVE AFTER PLUMB AND ELECTRIC. |