Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM04207
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/25/2000 | FRAMING | Approved | IVRS - Inspection 0000* | |
10/23/2000 | FRAMING | Partial Approval | IVRS - Inspection 0000*/NEED CLIP AND A35 AT REAR PORCH. | |
10/20/2000 | FRAMING | Denied | IVRS - Inspection 0999*/NOTE: ADD STUD AT HALL BATH AND FHA STRAP AT MAST/BATH EASTWALL. 1. HALL BATH FLANGE. 2. GAS LINE SECURE AT FIRPLACE. 3. CLIP REAR PORCH WHERE NEEDED. 4. BLK VENTS AT GARAGE 4 SIDES. 5. GROUT TUBS. 6. SECURE A/C LINES. | |
10/13/2000 | FRAMING | Denied | 1. STRAP SOLE PLATES 16GA METAL. 2. PROTECT ELECTRICAL ROMEX WITHIN 1 1/4. 3. FHA STRAP AT AC LINE. 4. PLUMBING NOT COMPLETE AT WASHER 5. NO GAS LINES INSTALLED. |