Permit: T00CM04206

Parcel: 141146910

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/28/2000 FRAMING Approved IVRS - Inspection 0000*
11/27/2000 FRAMING Denied IVRS - Inspection 0999*/GAS LINES NOT SUPPORTED ADEQUATELY (1 1/4" GAS LINE RESTING ON FAU DUCT IS NOT ACCEPTABLE).
11/22/2000 FRAMING Denied IVRS - Inspection 0999*
11/20/2000 FRAMING Denied IVRS - Inspection 0999*/1. SHIM TRIMMER/HEADER GAPS WHERE NEEDED. 2. INSTALL CRIPPLES UNDER FLOOR TRUSSES MUST BE FULL BEARING ON PATIO DOOR HEADER. 3. INSTALL 2X'S AT CANTALEVER WHERE POST IS MISSING, STRAP ACCROSS CANTALEVERBEAM, SHIM CRIPPLED. 4. SHEATH INTERIOR OF CHINMNEY CHASE PER PLAN. 5. STRAP ALL GAS PIPING WHERE NEEDED.