Permit: T00CM04201

Parcel: 141201690

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/11/2000 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
10/05/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0145*/1. NAIL SHEAR TRANSFER PANELS DOWN FORM ROOF WITH 16D NAILS (AT LEAST 4 NAILS PER PNL.). 2. CHECK PANELS ON NORTHSIDE OF ROOF-SOME NEED NAILING. 3. ADD ANCHOR BOLTS ALONG FLOOR PLATE WHERE NEEDED WITHIN 12" OF EACH END OF PLATES. TIGHTEN NUTS--ADD LARGE WASHERS WHERE HOLE IN FLOOR PLATE IS TOO LARGE FOR SMALL WASHERS. NUT AND WASHER SHOULD NOT SINK INTO WOOD. 4. ADD LONG STEEL STRAPS ACROSS BUTTED--PEAK--TOP PLATES. TIE WALL SECTIONS TOGETHER. 5. 'T' WIND BRACE SHOULD BE NAILED IN CENTER GROOVE NOT WINGS. 6. GARAGE SHEAR PANELING NEEDS NAILING AT SOME STUDS.