Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T00CM04118
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/05/2001 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection 0000* | |
03/28/2001 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection 0000*/NOTE: SEWER LINE FROM INSIDE WALL OF BASEMENT TO 2 LOCATIONS TO HCS OK INCLUDING 2 B.W.V.'S ROUGH DRAINS NOT IN. 1. ALL DRAIN AND WASTE FROM FIRST FLOOR ABOVE BASEMENT WILL HAVE TO BE CONNECTED TO MAIN SEWER LINE DOWN STREAM OF BACK WATER VALVES. REVISE PLUMBING PLAN AND HAVE APPROVED BY C.O.T. |