Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T00CM04118

Parcel: 117021090


Addresses:

1007 N 5TH AV


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T00CM04118

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/03/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/07/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RECEPTACLE OUTLETS AT KITCHEN ISLAND SHOWING REVERSE POLARITY AND AT BREAKFAST ROOM
2) NEED WALL PLATE COVER ON RECEPTACLE UNDER MAIN KITCHEN SINK
3) NEED NO-LOX LUBRICENT ON ALUMINIUM WIRES AT MAIN SERVICE PANEL
06/06/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ACCESS TO INSPECTION CALL BACK FOR INSPECTION TOMORROW LEAVE MSG WITH PHONE NUMBER