Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/19/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 12/15/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. HOLDOWN AT GARAGE FRONT NOT NAILED. 2. STRAP CORNERS WITH OVERLAPPING DOUBLE TOP PLATES. 3. TRUSS DRAWINGS NOT ON SITE. 4. O.S.B. ROOF SHEATHING MUST SPAN 2 BAYS (3 TRUSSES). 5. O.S.B. PANELS CANNOT BE INSTALLED PARALLEL TO TRUSSES. 6. ROOF SHETHING LOOSE. RENAIL ALL SHINERS. 7. GABLE END BRACING MUST BE ANILED THRU SHEATHING. 6/DT1 ALSO AT SHEAR PANELS. |
| 12/13/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/1. NEED TRUSS CALC'S AT SITE. 2. HPAHD NOT NAILED. |
| 12/11/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
NO PLAN ON SITE. |