Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/03/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 10/27/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/GARAGE POST CAPS MISSING INSIDE. 2. ENTRY COVER NOT CLIPPED PER PLAN OK TO DRY IN CHECK AT INTERMEDIATES. |
| 10/26/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0950* |
| 10/23/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0145*/1. GARAGE BEAM MISSING POST CAPS. 2. TJI NOT ALLOWED AS BARGE RAFTER. MUST BE DIMENTIONAL LUMBER SEE 34/S4 MUST BE 2 X 6 EAST AND WEST WALLS. 3. GARAGE WEST WALL CLIPS COVERED W/O INSPECTION EXPOSE. 4. TURN 4 X 6 POST AT ENTRY. 5. RAFTERS AND ENTRY NOT CLIPPED. SEE 32/S4. 6. CLIP KING STUDS AND HEADERS AND CRIPPLES. 7. CLIP MISSING SEE 26/S4. 8. SHEAR WALLS 1 AND 2 NOT BLOCKED. |