Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T00CM04064

Parcel: 13705501Q


Addresses:

1165 W IRVINGTON RD


Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Permit Number - T00CM04064

Inspection Description - PLUMBING - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
07/02/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) WATER HEATER PAN DRIAN OK 2.) GAS STRAPPING OK 3.) BREAK SINK OK 4.) CONTRACTOR TO CHANGE TOILET PAPER DISPENSERS 2 PLACES TO INSURE CENTERING TO SIDEWALL CLEARANCE. 5.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS 6.) UCC LEFT AT METER
07/02/2001 PLUMBING - FINAL Approved 1.) WATER HEATER PAN DRAIN OK 2.) GAS STRAPPIGN OK 3.) BREAK SINK OK 4.) CONTRACTOR TO CHANGE TOILET PAPER DISPENSERS 2 PLACES TO INSURE CENTERING TO SIDEWALL CLEARANCE 5.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS 6.) UCC LEFT AT METER
06/17/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*
06/15/2001 PLUMBING - FINAL Denied 1.)MINIMUM 15" FROM SIDEWALL OR OBSTRUCTION TO CENTERLINE OF WATER CLOSET.
2.) REDUCING PAN DRAIN FROM 1" TO 3/4" IS CONSIDERED AN OBSTRUCTION
3.) PLEASE INSTALL CORRECT STRAPS ON GAS LINE
4.) MISSING BREAK CABINET NOT AVAILABLE UNTIL 6-22-01
06/14/2001 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*1)NOT READY FOR INSPECTION.