Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/14/2000 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 12/13/2000 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1. INSTALL METAL IN FRONT OF ATTIC FURNACE FIREBOX. 2. REMOVE WIRES FROM AROUND FLUE PIPE. 3. REMOVE ALL UNUSED WIRES TOP OF ATTIC UNITS. 4. COMPLETE ALL AND RECALL. |
| 12/11/2000 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1. INSTALL MAX. 40 AMP FUSES A.C. 2. COMPLETE A.C. SCREEN WALL. 3. INSTALL BULB ATTIC. 4. MOVE DUCTWORK OUT OF FURNACE ACCESS ATTIC. 5. CONNECT GAS TO FIREPLACE. 6. GFCI KITCHEN NOT WORKING 7. RELOCATE KITCHEN PENINSULA ELECT. OUTLET TO END (EXISTING NOT PER CODE) 8. STOPPED INSPECTION. 9. COMPLETE ALL. 10. RECALL WHEN READY. |